{"product_id":"maretron-mpower-clmd16-power-module-with-a3708-a3709-a3710","title":"Maretron MPower CLMD16 Power Module with A3708 A3709 \u0026 A3710","description":"\u003cdiv data-content-type='\\\"row\\\"' data-appearance='\\\"contained\\\"' data-element='\\\"main\\\"'\u003e\u003cdiv data-enable-parallax='\\\"0\\\"' data-parallax-speed='\\\"0.5\\\"' data-background-images='\\\"{}\\\"' data-background-type='\\\"image\\\"' data-video-loop='\\\"true\\\"' data-video-play-only-visible='\\\"true\\\"' data-video-lazy-load='\\\"true\\\"' data-video-fallback-src='\\\"\\\"' data-element='\\\"inner\\\"' data-pb-style='\\\"639072572C827\\\"'\u003e\n\u003cdiv data-content-type='\\\"text\\\"' data-appearance='\\\"default\\\"' data-element='\\\"main\\\"' data-pb-style='\\\"639072572C831\\\"'\u003e\u003cul\u003e \u003cli\u003eNMEA 2000 Interface\u003c\/li\u003e \u003cli\u003eIP67 Rated\u003c\/li\u003e \u003cli\u003eIgnition Protected\u003c\/li\u003e \u003cli\u003eOpto-isolated from NMEA 2000 eliminating potential ground loops\u003c\/li\u003e \u003cli\u003e16 dimmable Electronic Circuit Breakers (ECBs) for On\/Off Control over NMEA 2000 network (4 x 25A 12 x 12A)\u003c\/li\u003e \u003cli\u003eIndividual breaker electrical current monitoring\u003c\/li\u003e \u003cli\u003eBreakers can have Power-Up states defined (ON OFF or previous states)\u003c\/li\u003e \u003cli\u003eBreakers can be Locked against inadvertent actuation.\u003c\/li\u003e \u003cli\u003eCapacitive touch switches for local control of all loads\u003c\/li\u003e \u003cli\u003eAll inputs and outputs protected against short to Power and short to Ground\u003c\/li\u003e \u003cli\u003eAutomatic ECB overcurrent shutdown\u003c\/li\u003e \u003cli\u003eAutomatic ECB thermal shutdown (Overtemperature Protection)\u003c\/li\u003e \u003cli\u003e8 discrete digital input channels capable of sensing +ve or ground signals\u003c\/li\u003e \u003cli\u003e2 resistive analog input channels\u003c\/li\u003e \u003cli\u003e1 x 4-20mA current loop input channel\u003c\/li\u003e \u003c\/ul\u003e\u003c\/div\u003e\n\u003cdiv data-content-type='\\\"html\\\"' data-appearance='\\\"default\\\"' data-element='\\\"main\\\"' data-pb-style='\\\"639072572C838\\\"'\u003e\n\u003ca class='\\\"pagebuilder-button-primary\\\"' href='\\\"https:\/\/www.dropbox.com\/s\/334ewsotf1wk5p2\/CLMD16%20Datasheet.pdf?dl=0\\\"' target='\\\"_blank\\\"' style='\\\"text-align:' center font-weight: normal\u003e \u003ci class='\\\"fas' fa-file-alt\u003e\u003c\/i\u003e \u003cspan data-element='\\\"link_text\\\"' style='\\\"font-weight:'\u003e Datasheet\u003c\/span\u003e \u003c\/a\u003e \u003ca class='\\\"pagebuilder-button-primary\\\"' href='\\\"https:\/\/www.maretron.com\/support\/manuals\/CLMD16UM_2.0.pdf\\\"' target='\\\"_blank\\\"' style='\\\"text-align:' center font-weight: normal\u003e \u003ci class='\\\"fas' fa-book\u003e\u003c\/i\u003e \u003cspan data-element='\\\"link_text\\\"' style='\\\"font-weight:'\u003e Manual\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type='\\\"text\\\"' data-appearance='\\\"default\\\"' data-element='\\\"main\\\"' data-pb-style='\\\"639072572C83E\\\"'\u003e\n\u003cp\u003eFor larger breakers and more circuits the MPower CLMD16 is a 16-Channel DC Load Controller Module. Four of the 16 breakers handle a maximum of 25 amps and twelve breakers handle a maximum of 12 amps with a total current capacity of 125 Amps. Additionally circuits can be paralleled.\u003c\/p\u003e \u003cp\u003eThe CLMD16 also supports two H-Bridge reversing polarity circuits that can be used for loads such as engine hatches passerelles trim tabs etc. The CLMD16 has 8 inputs for hard-wired switches that can be used to switch breaker states or as inputs for other data such as bilge alarms or hatch positions etc. There are 3 inputs capable of monitoring tank levels.\u003c\/p\u003e \u003cp\u003eThe CLMD16 handles many DC load types such as lights pumps motors and electronics. An added benefit of the CLMD16 is that it reports the current through each of the 16 breakers. This allows you to determine if loads are drawing too much or too little electrical current. This information can be used to report overcurrent faults and under-current conditions such as burnt-out bulbs.\u003c\/p\u003e \u003cp\u003eMonitor and control onboard electrical and electronic systems and reset circuits onboard and remotely with the following devices:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAny 3rd party MFD that supports standard digital switching PGNs\u003c\/li\u003e \u003cli\u003eMaretron MBB300C Black Box - Garmin OneHelmTM - Raymarine LightHouse 3\u003c\/li\u003e \u003cli\u003eMaretron TSM Series Dedicated Touchscreen\u003c\/li\u003e \u003cli\u003eMPower VMM6 Digital Switch Module\u003c\/li\u003e \u003cli\u003eMPower CKM12 Keypad\u003c\/li\u003e \u003cli\u003eAny device running Maretron’s award-winning N2KView V3 Software\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIn The Box\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eCLMD16 - 16 Channel Load Controller Module\u003c\/li\u003e \u003cli\u003eA3708 - Output (J2) Mating Connector with 1m Flying Leads\u003c\/li\u003e \u003cli\u003eA3709 - Output (J1) Mating Connector with 1m Flying Leads\u003c\/li\u003e \u003cli\u003eA3710 - J3 (I\/O Gen Purpose) Harness Kit with 1m Flying Leads\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cstyle\u003e#html-body [data-pb-style=\\\"639072572C827\\\"]{justify-content: flex-start; display: flex; flex-direction: column; background-position: left top; background-size: cover; background-repeat: no-repeat; background-attachment: scroll; border-style: none; border-width: 1px; border-radius: 0px; margin: 0px 0px 10px; padding: 10px;}#html-body [data-pb-style=\\\"639072572C831\\\"]{border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;}#html-body [data-pb-style=\\\"639072572C838\\\"]{border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;}#html-body [data-pb-style=\\\"639072572C83E\\\"]{border-style: none; border-width: 1px; border-radius: 0px; margin: 0px; padding: 0px;}\u003c\/style\u003e","brand":"Maretron","offers":[{"title":"Default","offer_id":46883958128971,"sku":"468-CLMD16-R","price":1390.5,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/7400\/5323\/files\/468-clmd16-r.jpg?v=1694104483","url":"https:\/\/www.parkeradams-superstore.com\/products\/maretron-mpower-clmd16-power-module-with-a3708-a3709-a3710","provider":"Parker Adams Superstore","version":"1.0","type":"link"}