Victron BPR000100400 Battery Protect 12/24V - 100A
Victron BPR000100400 Battery Protect 12/24V - 100A
SKU:792-BPR000100400
- Voltage: 12/24V
- Max. Continuous Load Current: 100A
- Peak Current (During 30 Seconds): 600A
- Operating Voltage Range: 6 –35V
- Alarm Output Delay: 12 seconds
- Max. Load on Alarm Output: 50 mA
- Load Disconnect Delay: 90 seconds
- Load Reconnect Delay: 30 seconds
- Protection Category: Electronics: IP67 (potted) Connections: IP00
- Connection: M8
- Mounting Torque: 9 Nm
- Bluetooth Enabled: No
- Dimensions: H59 x W42 x D115mm
- Weight: 0.5Kg
- Warranty: 5 Years
The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.
The BatteryProtect is not designed for reverse currents from charging sources.
Features
12/24V auto ranging
The BatteryProtect automatically detects system voltage.
Programming made easy
The BatteryProtect can be set to engage / disengage at several different voltages.
The seven segment display will indicate which setting has been chosen.
A special setting for Li-ion batteries
In this mode the BatteryProtect can be controlled by the VE.Bus BMS.
Ultra low current consumption
This is important in case of Li-ion batteries especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.
Over voltage protection
To prevent damage to sensitive loads due to over voltage the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.
Ignition proof
No relays but MOSFET switches and therefore no sparks.
Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail max. current 50 mA. The alarm output is typically used to activate a buzzer LED or relay.
Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example) the load will not be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.